Sprinkler_Pendent_Hosted_USACE

Category: Sprinklers
Family NameCategoryType NameApprovalsAssembly CodeAssembly DescriptionBody HeightBody LengthBody MaterialCELConnector DiameterConnector RadiusCoverageDefault ElevationDescriptionDiameterDistrict SourceElementEscutcheonEscutcheon DiameterEscutcheon RadiusEscutcheon ThicknessFlow RateGuardHazardKfactorMax PressureMax SpacingMax Working PressureMin SpacingModelNominal DiameterNominal LengthNominal RadiusNOMINALMAKEINNPT DIANPT RADNPTRADOALOmniClassOmniClass NumberOmniClass TitleOrificeOrifice SizeOverall LengthPlan SymbolField49Pressure ClassProtrusionRecess HeightRecessed DiaRecessed Dia 1ResponseSprinkler LengthTemperatureType of FamilyUSACE Master Template File
Sprinkler_Pendent_Hosted_USACESprinklers1/2" Pendent0"Standard8' - 0"Louisville District1"0"0"5.61"0"23.65.70.17.11.24Fire Fighting Sprinkler HeadsStandard1"2"Standard2"Standard135 °FLoadable FamilyUSACE_Sprinklers.rvt
Sprinkler_Pendent_Hosted_USACESprinklers1/2" Pendent on Drop0"Standard8' - 0"Louisville District1"0"0"5.61"0"23.65.70.17.11.24Fire Fighting Sprinkler HeadsStandard1"2"Standard2"Standard135 °FLoadable FamilyUSACE_Sprinklers.rvt
Sprinkler_Pendent_Hosted_USACESprinklers1/2" Pendent on Drop with Guard0"Standard8' - 0"Louisville District1"0"0"5.61"0"23.65.70.17.11.24Fire Fighting Sprinkler HeadsStandard1"2"Standard2"Standard135 °FLoadable FamilyUSACE_Sprinklers.rvt
Sprinkler_Pendent_Hosted_USACESprinklers1/2" Pendent with Guard0"Standard8' - 0"Louisville District1"0"0"5.61"0"23.65.70.17.11.24Fire Fighting Sprinkler HeadsStandard1"2"Standard2"Standard135 °FLoadable FamilyUSACE_Sprinklers.rvt
Sprinkler_Pendent_Hosted_USACESprinklers3/4" Pendent0"Standard8' - 0"Louisville District1"0"0"8.01"0"23.65.70.17.11.24Fire Fighting Sprinkler HeadsStandard1"3"Standard2"Standard135 °FLoadable FamilyUSACE_Sprinklers.rvt
Sprinkler_Pendent_Hosted_USACESprinklers3/4" Pendent on Drop0"Standard8' - 0"Louisville District1"0"0"8.01"0"23.65.70.17.11.24Fire Fighting Sprinkler HeadsStandard1"3"Standard2"Standard135 °FLoadable FamilyUSACE_Sprinklers.rvt
Sprinkler_Pendent_Hosted_USACESprinklers3/4" Pendent on Drop with Guard0"Standard8' - 0"Louisville District1"0"0"8.01"0"23.65.70.17.11.24Fire Fighting Sprinkler HeadsStandard1"3"Standard2"Standard135 °FLoadable FamilyUSACE_Sprinklers.rvt
Sprinkler_Pendent_Hosted_USACESprinklers3/4" Pendent with Guard0"Standard8' - 0"Louisville District1"0"0"8.01"0"23.65.70.17.11.24Fire Fighting Sprinkler HeadsStandard1"3"Standard2"Standard135 °FLoadable FamilyUSACE_Sprinklers.rvt